 General Data
  | 
 
 
 | 
 Ambient temperature range for operation
  | 
 
 –20°C to +40°C (-4°F to 104°F)
  | 
 
 
 | 
 Protection class
  | 
 
 IP67
  | 
 
 
 | 
 Weight
  | 
 
 6.7 kg (without camera and lens)
  | 
 
 
 | 
 Empty volume
  | 
 
 5.06 l
  | 
 
 
 | 
 External dimensions (without sun shield)
  | 
 
 D = 170 mm, L = 408 mm
  | 
 
 
 | 
 Housing material / Surface
  | 
 
 Nickel-plated aluminium / Powder coated
  | 
 
 
 | 
 Protection window
  | 
 
 Germanium, double-sided AR Coated, externally with additional hard-carbon layer
  | 
 
 
 | 
 Maximum power of the additional heater
  | 
 
 16 W
  | 
 
 
 | 
 Operating voltage
  | 
 
 24 V DC
  | 
 
 
 | 
 Maximum electric connection power
  | 
 
 60 W
  | 
 
 
 | 
 Power cable / Power cable configuration
  | 
 
 Helukabel 37264 / Pigtail
  | 
 
 
 | 
 Length of power cable
  | 
 
 4 m (13 ft.)
  | 
 
 
 | 
 Integrated controller
  | 
 
 4-port switch with 2 × fiber-optic LC 100Base-FX or 2 × RJ45(10/100) up-links, ring-topology support for reduced cabling effort, 2 × internal temperature sensors, air humidity and pressure sensor, digital output module controllable via Modbus TCP/IP or web interface to enable turning the heater on/off
  | 
 
 
 | 
 Ethernet medium
  | 
 
 Multi-mode breakout fiber AT-V(ZN)Y(ZN)Y 4G50/125 OM2
  | 
 
 
 | 
 Length of Ethernet cable
  | 
 
 4 m (13 ft.)
  | 
 
 
 | 
 Ethernet, configuration
  | 
 
 Pigtail with FC-connector
  | 
 
 
 | 
 Explosion protection-specific data
  | 
 
 
 | 
 For use in EX zone
  | 
 
 1, 2, 21, and 22
  | 
 
 
 | 
 Ignition protection category
  | 
 
 Flame-proof enclosure “d”
  | 
 
 
 | 
 Maximum surface temperature (according to temperature class T6)
  | 
 
 Maximum 85°C
  | 
 
 
 | 
 ATEX certification (version -AXC)
  | 
 
 EX-Protection Gas: II 2G Ex d IIC T6 Gb, EX-Protection Dust: II 2D Ex tb IIC T85° Db
  | 
 
 
 | 
 Verification certificate
  | 
 
 ZELM 12 ATEX 0485 X
  | 
 
 
 | 
 Imaging and optical data
  | 
 
 
 | 
 IR resolution
  | 
 
 320 × 240 pixels
  | 
 
 
 | 
 Thermal sensitivity/NETD
  | 
 
 < 0.05°C @ +30°C (+86°F) / 50 mK
  | 
 
 
 | 
 Field of view (FOV) / Focal length
  | 
 
 25° × 18.8° with 18 mm (0.7 in.) lens or 45° × 33.8° with 9.66 mm (0.38 in.) lens
  | 
 
 
 | 
 Minimum focus distance
  | 
 
 0.4 m (1.31 ft.)
  | 
 
 
 | 
 Spatial resolution (IFOV)
  | 
 
 1.36 mrad with 25° lens or 2.59 mrad with 45° lens
  | 
 
 
 | 
 Lens identification
  | 
 
 Automatic
  | 
 
 
 | 
 F-number
  | 
 
 1.3
  | 
 
 
 | 
 Image frequency
  | 
 
 30 Hz
  | 
 
 
 | 
 Focus
  | 
 
 Automatic or manual (built in motor)
  | 
 
 
 | 
 Zoom
  | 
 
 1–8× continuous, digital, interpolating zooming on images
  | 
 
 
 | 
 Detector data
  | 
 
 
 | 
 Detector type
  | 
 
 Focal Plane Array (FPA), uncooled microbolometer
  | 
 
 
 | 
 Spectral range
  | 
 
 7.5–13 μm
  | 
 
 
 | 
 Detector pitch
  | 
 
 25 μm
  | 
 
 
 | 
 Detector time constant
  | 
 
 Typical 12 ms
  | 
 
 
 | 
 Measurement
  | 
 
 
 | 
 Object temperature range
  | 
 
 –20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
  | 
 
 
 | 
 Accuracy
  | 
 
 ±2°C (±3.6°F) or ±2% of reading
  | 
 
 
 | 
 Measurement analysis
  | 
 
 
 | 
 Spotmeter
  | 
 
 10
  | 
 
 
 | 
 Area
  | 
 
 10 boxes with max./min./average/position
  | 
 
 
 | 
 Isotherm
  | 
 
 1 with above/below/interval
  | 
 
 
 | 
 Measurement option
  | 
 
 Measurement Mask Filter Schedule response: File sending (ftp), email (SMTP)
  | 
 
 
 | 
 Difference temperature
  | 
 
 Delta temperature between measurement functions or reference temperature
  | 
 
 
 | 
 Reference temperature
  | 
 
 Manually set or captured from any measurement function
  | 
 
 
 | 
 Atmospheric transmission correction
  | 
 
 Automatic, based on inputs for distance, atmospheric temperature and relative humidity
  | 
 
 
 | 
 Optics transmission correction
  | 
 
 Automatic, based on signals from internal sensors
  | 
 
 
 | 
 Emissivity correction
  | 
 
 Variable from 0.01 to 1.0
  | 
 
 
 | 
 Reflected apparent temperature correction
  | 
 
 Automatic, based on input of reflected temperature
  | 
 
 
 | 
 External optics/windows correction
  | 
 
 Automatic, based on input of optics/window transmission and temperature
  | 
 
 
 | 
 Measurement corrections
  | 
 
 Global and individual object parameters
  | 
 
 
 | 
 Alarm
  | 
 
 
 | 
 Alarm functions
  | 
 
 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
  | 
 
 
 | 
 Alarm output
  | 
 
 Digital Out, log, store image, file sending (ftp), email (SMTP), notification
  | 
 
 
 | 
 Set-up
  | 
 
 
 | 
 Color palettes
  | 
 
 Color palettes (BW, BW inv, Iron, Rain)
  | 
 
 
 | 
 Set-up commands
  | 
 
 Date/time, Temperature°C/°F
  | 
 
 
 | 
 Storage of images
  | 
 
 
 | 
 Storage media
  | 
 
 Built-in memory for image storage
  | 
 
 
 | 
 File formats
  | 
 
 Standard JPEG, 16-bit measurement data included
  | 
 
 
 | 
 Ethernet
  | 
 
 
 | 
 Ethernet
  | 
 
 Control, result and image
  | 
 
 
 | 
 Ethernet, type / standard
  | 
 
 100 Mbps / IEEE 802.3
  | 
 
 
 | 
 Ethernet, configuration
  | 
 
 Pigtail with FC-connector (fiber)
  | 
 
 
 | 
 Ethernet, communication
  | 
 
 TCP/IP socket-based FLIR proprietary
  | 
 
 
 | 
 Ethernet, video streaming
  | 
 
 MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5
  | 
 
 
 | 
 Ethernet, image streaming
  | 
 
 16-bit 320 × 240 pixels @ 7-8 Hz - Radiometric
  | 
 
 
 | 
 Ethernet, protocols
  | 
 
 Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
  | 
 
 
 | 
 Shipping information
  | 
 
 
 | 
 Infrared camera with lens, in explosion-proof housing, cardboard box, Printed documentation, User documentation CD-ROM, Utility CD-ROM
  |